Omron FQ2-S/CH Series User Manual page 275

Smart camera
Hide thumbs Also See for FQ2-S/CH Series:
Table of Contents

Advertisement

Save Calibration Data
Saves the data for the specified calibration number as a file to the SD card inserted in the Touch Finder.
The destination for scene data is the following fixed directory on the SD card.
\Sensor name\CLB
The file name is not case sensitive. The file name extension can be omitted.
Command (PLC to Sensor)
First word of
command
12 to 15
area
+2
1010
+3
0000
+4
0000
+5
0000
+6
0000
+7
0000
+8
0000
:
:
+37
0000
*1
Saved as a file named Calibration_***.clb. (***: Specified file number)
Response (Sensor to PLC)
First word of
response area
12 to 15
+2
1010
+3
0000
+4
0000
+5
0000
FQ2-S/CH User's Manual
for Communications Settings
Bits
8 to 11
4 to 7
0000
0000
0000
0111
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
:
:
0000
0000
Bits
8 to 11
4 to 7
0000
0000
0000
0111
0000
0000
0000
0000
Description
0 to 3
0000
Command code
0000
0000
Calibration number to save
0000
0000
• EtherNet/IP,
PROFINET
0000
File number to
*1
save (0 to 999)
0000
:
0000
---
Description
0 to 3
0000
Command code
The command code for which the
0000
response applies is stored.
0000
Response code
Command execution result
0000
0: OK, FFFFFFFF: NG
• PLC link
File name to
save
64 characters
max.
The file name
extension (.clb)
can be omitted.
Refer to
Specifying Char-
acter Strings:
p. 206
273
Command Control

Advertisement

Table of Contents
loading

Table of Contents