Acquire Registered Image
This command loads a registered image saved to the SD card or PC Tool as the measurement image.
The registered image is the latest image or a logging image that has been assigned a number between 0 and
999 and has been registered in advance with the Set a Registered Image command.
Set a Registered Image p.401
Command Format
MRC
SRC
Sensor command code (4
(1 byte)
(1 byte)
bytes)
28
0F
00108020
Response Format
MRC
SRC
MRES
(1 byte)
(1 byte)
(1 byte)
28
0F
End code
End Codes
End code (hex)
0000
Command execution ended normally.
FFFF
Command execution ended in an error.
Parameter Descriptions
Registered image num-
Specifies the image to be loaded as the measurement image.
ber
The image is registered in advance with the Set a Registered Image command and assigned a number.