Save Latest Input Image Data
Saves the latest input image to the SD card inserted in the Touch Finder as ifz data.
The destination for image data is the following fixed directory on the SD card.
\Sensor name\CAPTURE\Number
*
Number is a five digit number starting from 00000. The images are saved in increments of 100 images for each number, and when there
are over 100 images, the directory with the next number is created.
Format
MRC
SRC
Sensor command code (4
(1 byte)
(1 byte)
bytes)
28
0F
00704020
Response Format
MRC
SRC
MRES
(1 byte)
(1 byte)
(1 byte)
28
0F
End code
End Codes
End code (hex)
Description
0000
Command execution ended normally.
FFFF
Command execution ended in an error.
Parameter Descriptions
Image data file name
Specifies the image data file name to save.
The file name extension (.ifz) can be omitted.
Important
• If the specified file name already exists, this existing file will be overwritten.
• Do not turn off power to the Sensor until there is a response.
FQ2-S/CH User's Manual
for Communications Settings
*
Image data file name
(4 to 64 bytes)
64 characters max.
SRES
Sensor command code (4 bytes)
(1 byte)
00704020