Omron FQ2-S/CH Series User Manual page 239

Smart camera
Hide thumbs Also See for FQ2-S/CH Series:
Table of Contents

Advertisement

System
Type
Item
data num-
ber
255
RS-232C
All OUT sig-
Interface
nals polarity
Sensor
Data Unit
256
RS-232C
Parallel com-
Interface
mand mode
Sensor
Data Unit
257
RS-232C
ACK signal ON
Interface
period
Sensor
Data Unit
Acquire Terminal Offset Data
This command acquires the terminal offset data that is added to the IN0 to IN4 command parameters when
executing parallel commands
After the Set Terminal Offset command is executed, the response code is OK when this command is executed.
If no value has been set with the Set Terminal Offset command, OK "0" is returned as response code and
"0000" is returned for the terminal offset value.
Set Terminal Offset Data: p.251
Command (PLC to Sensor)
First word of com-
mand area
12 to 15
+2
0100
+3
0000
Response (Sensor to PLC)
First word of
response area
12 to 15
+2
0100
+3
0000
+4
0000
+5
0000
+6
0000
+7
0000
FQ2-S/CH User's Manual
for Communications Settings
Data
Range
size
4
0: Positive
1: Negative
4
0: Standard mode
1: Expanded mode
4
1 to 10,000
Bits
8 to 11
4 to 7
0 to 3
0000
0110
0000
0000
0100
0000
Bits
8 to 11
4 to 7
0 to 3
0000
0110
0000
0000
0100
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
Description
Specifies the polarity for all
output signals.
Defines the parallel com-
mand mode.
Specifies the ACK signal
ON output time (x0.1 ms)
when outputting the ACK
signal. This setting is
applicable for external trig-
ger input only.
Description
Command code
Description
Command code
The command code for which the response
applies is stored.
Response code
Command execution result
0: OK, FFFFFFFF: NG
Terminal offset value
Value added to the IN0 to IN4 command
parameters when executing parallel com-
mands
237
Command Control

Advertisement

Table of Contents
loading

Table of Contents