Omron FQ2-S/CH Series User Manual page 452

Smart camera
Hide thumbs Also See for FQ2-S/CH Series:
Table of Contents

Advertisement

Save Measurement Data
Saves measurement data saved in the Sensor's memory by the logging function to the SD card inserted in the
Touch Finder as csv data.
The destination for measurement data is the following fixed directory on the SD card.
\Sensor name\LOGDATA
The file name is automatically created as follows.
YYYY_MM_DD-HH_mm_ss.csv
The date and time that make up the measurement data file name are not the date and time that the
measurement was performed, they are the date and time the measurement data file was saved from the
Sensor to the Touch Finder SD card by this command.
Format
MRC
SRC
(1 byte)
(1 byte)
28
0F
Response Format
MRC
SRC
(1 byte)
(1 byte)
28
0F
End Codes
End code (hex)
0000
FFFF
Important
Do not turn off power to the Sensor until there is a response.
450
Command Control
Time that the measurement data was saved to the Touch Finder SD card
Date that the measurement data was saved to the Touch Finder SD card
Sensor command code (4
bytes)
00707000
MRES
SRES
(1 byte)
(1 byte)
End code
Description
Command execution ended normally.
Command execution ended in an error.
Sensor command code (4 bytes)
00707000
FQ2-S/CH User's Manual
for Communications Settings

Advertisement

Table of Contents
loading