Omron FQ2-S/CH Series User Manual page 438

Smart camera
Hide thumbs Also See for FQ2-S/CH Series:
Table of Contents

Advertisement

Load All Calibration Data
This command loads all calibration data that is stored on the SD card inserted in the Touch Finder.
The source for all calibration data is the following fixed directory on the SD card.
\Sensor name\CGP
Format
MRC
SRC
(1 byte)
(1 byte)
28
0F
Response Format
MRC
SRC
(1 byte)
(1 byte)
28
0F
End Codes
End code (hex)
0000
FFFF
Parameter Descriptions
All calibration data name Specifies the all calibration data file name to be loaded.
Important
Do not turn off power to the Sensor until there is a response.
436
Command Control
Sensor command code (4
bytes)
0060B000
MRES
SRES
(1 byte)
(1 byte)
End code
Command execution ended normally.
Command execution ended in an error.
The file name extension (.cgp) can be omitted.
All scene data file name
(4 to 64 bytes)
64 characters max.
Sensor command code (4 bytes)
0060B000
Description
FQ2-S/CH User's Manual
for Communications Settings