Omron FQ2-S/CH Series User Manual page 69

Smart camera
Hide thumbs Also See for FQ2-S/CH Series:
Table of Contents

Advertisement

*1:
You can change the settings of when the GATE signal is turned ON after the measurement data is output and the length of time that the
GATE signal will remain ON.
Setting the Output Timing for the GATE Signal: p. 66
Note
The GATE signal will not be output if there is no data set for parallel judgement output and parallel data output.
If only the OR signal is output, read the OR signal when the BUSY signal turns OFF.
 Single Measurement
Example: Three Data Items Set for Parallel Data Output
Timing Chart
Run Mode entered.
ON
RUN signal
OFF
ON
TRIG signal
OFF
ON
BUSY signal
OFF
ON while measurements are being processed
OR signal
D0 to D15
signals
ON
GATE signal
OFF
1
The RUN signal turns ON when measurements are enabled and the Sensor is in Run Mode.
2
Turn ON the TRIG signal while the BUSY signal is OFF.
3
Measurement begins and the BUSY signal is turned ON during the measurement process.
4
When the measurement has been finished, the measurement results are output using an OR sig-
nal and the D0 to D15 signals, and the BUSY signal is turned OFF.
*1
You can also set the [BUSY output] parameter so that the BUSY signal is turned OFF after the completion of data logging, image logging,
or displaying results.
5
After the BUSY signal turns OFF, the GATE signal is turned ON when the time that is set in the
[GATE ON delay] parameter in the communications settings has elapsed.
6
The GATE signal is turned ON, and then the GATE signal is turned OFF when the time that is set
in the [Output time] parameter in the communications settings has elapsed.
*2
Set the GATE ON delay and output time for the GATE signal so that the total time does not exceed the output period.
FQ2-S/CH User's Manual
for Communications Settings
Measurement done (BUSY output OFF)
External device
(1) Measurement processing
and results output (OR and
D0 to D15)
(2) GATE signal
ON for 1 ms min.
(depends on BUSY output conditions)
Turned ON when overall judgement is NG.
(Polarity of all output signals: Positive)
Data 0
GATE ON delay
Output time
Output period
The total output time is as follows: Output period × Number of output data items.
Controlling Operation and Outputting Data with a Parallel Interface Sensor Data Unit
FQ2
*1
Setup Mode entered.
Data 1
Data 2
*1
*2
*2
67