Omron FQ2-S/CH Series User Manual page 392

Smart camera
Hide thumbs Also See for FQ2-S/CH Series:
Table of Contents

Advertisement

<Execution command response format>
When the Command Is Processed Normally
Model dictionary data (binary)
O
K
CR
Delimiter
When the Command Is Not Processed Normally
E
R
CR
Delimiter
<Parameter Descriptions>
Model dictionary data number
Model dictionary data size
Model dictionary data (binary)
PREDGRSAVEB (Check) / DGRSAVEB (Execute)
Outputting all model dictionary data (binary data)
This command outputs all model dictionary data in binary data format.
To execute this command, two types of commands are used, a confirmation command and an execution
command.
For how to execute the command using the confirmation command and the execution command, refer to
Binary Data File Load and Save Commands: p. 188.
<Confirmation command format>
Before all model dictionary data is output in binary data format, a check is performed to determine if the data
can be received by the external device that will receive the data.
P
R
E
D
<Confirmation command response format>
When the Command Is Processed Normally
All model dictionary data size
O
K
CR
Delimiter
390
Command Control
CR
Delimiter
Specifies the model dictionary data number (integer type) you want to output.
Specify 0 to 31.
Number of bytes of model dictionary data to output (integer type)
Model dictionary data to output (binary data)
G
R
S
A
V
E
CR
Delimiter
B CR
Delimiter
FQ2-S/CH User's Manual
for Communications Settings

Advertisement

Table of Contents
loading