Acquire Execution Mode
Acquires the FQ2 execution status (execution mode).
Command Format
MRC
SRC
Sensor command code (4
(1 byte)
(1 byte)
bytes)
28
0F
0020F000
Response Format
MRC
SRC
MRES
(1 byte)
(1 byte)
(1 byte)
28
0F
End code
End Codes
End code (hex)
0000
Command execution ended normally.
FFFF
Command execution ended in an error.
Parameter Descriptions
Execution mode
This command acquires the FQ2 execution mode
1: Run mode
2: Stop mode
10: Adjust mode
11: IO monitor setup mode
*
The execution mode is classified into the following modes depending on the FQ2 execution status.
• Run mode:
The mode to run actual measurements. I/O is possible with external devices such as a PLC.
• Stop mode:
This mode is for monitoring/controlling the output status of the parallel signals through communication commands only.
Therefore, I/O that is unrelated to parallel terminal control is not possible.
• Input:
Parallel signal input is not possible. Command input is not possible. (However, the terminal status monitor, set-
ting commands can be used)
• Output: Parallel signal output is possible. Data output is not possible.
• Adjust mode: The status where Touch Finder is connected and the Setup display is displayed.
This mode is for configuring settings and making adjustments, so measurement processing, I/O signals from external
devices, and command input are not possible.
• IO monitor setup mode:The status where Touch Finder is connected and the IO monitor in the Setup display is displayed.
FQ2-S/CH User's Manual
for Communications Settings
SRES
Sensor command code (4 bytes) Execution mode
(1 byte)
0020F000
Description
(4 bytes)
Execution mode
*
.
409
Command Control