Input Area
(response
7
6
area)
+4
+5
+6
+7
+8
+9
+10
+11
+12
+13
+14
+15
Signal
Signal name
FLG
Control Command
Completed
BUSY
Command Execu-
tion Active
READY
Trigger Input
Ready
OR
Overall judgement This signal turns ON when the overall judgement is NG.
ERR
Error
RUN
Run Mode
FQ2-S/CH User's Manual
for Communications Settings
Bits
5
4
3
2
Command code
Response code
Response data
This signal turns ON when the Sensor completes execu-
tion of the control command.
(This signal turns ON after the control command code,
response code, and response data have been stored.)
This signal automatically turns OFF when the Control
Command Execution Bit (EXE) is turned OFF by the user
(external device).
This signal is ON while the Sensor cannot execute a con-
trol command.
This signal is OFF while the Sensor can execute a control
command.
This signal turns OFF when the Sensor cannot execute a
control command.
This signal turns ON when the Sensor can execute a con-
trol command.
Even if parallel signal OR output is set to "One-shot Out-
put", this signal does not support One-shot Output.
This signal turns OFF when overall judgement is OK.
This signal turns ON when an error is detected in the Sen-
sor.
This signal turns OFF when the user (PLC) performs re-
measurement or error clear takes place (Error Clear Sig-
nal: ON) after an error is cleared.
This signal is ON while the Sensor is in Run Mode.
This signal is OFF while the Sensor is not in Run Mode.
Outputting Data and Controlling Operation through PROFINET
Description
1
0
Command code (32 bits)
Response code (32 bits)
Response data (32 bits)
Function
Application
method
Command/
response com-
munications
Command/
response com-
munications
Command/
response com-
munications
Command/
response com-
munications
Sensor status
change output
Sensor status
change output