Set Inspection Item Data
This command sets the parameters and measurement ranges of the specified inspection item.
Format
MRC
SRC
Sensor command code (4
(1 byte)
(1 byte)
bytes)
28
0F
00501020
Response Format
MRC
SRC
MRES
(1 byte)
(1 byte)
(1 byte)
28
0F
End code
End Codes
End code (hex)
0000
Command execution ended normally.
FFFF
Command execution ended in an error.
Parameter Descriptions
Inspection item number
Specifies the number of the inspection item to set. (0 to 31)
External reference num-
Specifies the external reference number.
ber
Section 9-2 External Reference Parameters
in Sensor FQ2-S/CH Series User's Manual (Cat. No. Z337)
Setting
Specifies the set value.
Section 9-2 External Reference Parameters
in Sensor FQ2-S/CH Series User's Manual (Cat. No. Z337)
FQ2-S/CH User's Manual
for Communications Settings
Inspection item number (4 bytes) External reference
Inspection item number from 00
to 1F (2 digits max.)
SRES
Sensor command code (4 bytes)
(1 byte)
00501020
Description
Set value (4 bytes)
number (4 bytes)
External reference
Set value (1,000
number
times the actual
value)
Command Control