Omron FQ2-S/CH Series User Manual page 270

Smart camera
Hide thumbs Also See for FQ2-S/CH Series:
Table of Contents

Advertisement

Save All Scene Data
This command saves all scene data as a file to the SD card inserted in the Touch Finder.
The destination for all scene data is the following fixed directory on the SD card.
\Sensor name\SGP
The file name is not case sensitive. The file name extension can be omitted.
Command (PLC to Sensor)
First word of com-
mand area
+2
+3
+4
+5
+6
:
+35
*1
Saved as a file named SceneGroup_***.sgp. (***: Specified file number)
Response (Sensor to PLC)
First word of
response area
+2
+3
+4
+5
268
Command Control
Bits
12 to 15
8 to 11
4 to 7
0010
0000
0000
0000
0000
0111
0000
0000
0000
0000
0000
0000
0000
0000
0000
:
:
0000
0000
0000
Bits
12 to 15
8 to 11
4 to 7
0010
0000
0000
0000
0000
0111
0000
0000
0000
0000
0000
0000
0 to 3
0000
Command code
0000
0000
• EtherNet/IP,
PROFINET
0000
File number to load
(0 to 999)*1
0000
:
:
0000
0 to 3
0000
Command code
Response target command codes
0000
0000
Response code
Command execution result
0000
0: OK, FFFFFFFF: NG
Contents
• PLC link
File name to save
64 characters max.
The file name exten-
sion (.sgp) can be
omitted.
Refer to
---
Specifying Character
Strings: p. 206
Contents
FQ2-S/CH User's Manual
for Communications Settings

Advertisement