Note
The timing for updating the OR signal and the ON time after judgement processing can be adjusted.
Adjusting the judgement output timing: p. 42
Getting Individual Judgements and Expression Judgements
Up to three judgement results of individual inspection items (item judgement signals OR0 to OR31) and
expression judgements (expression 0 judgement to expression 31 judgement) can be assigned to terminals
OUT0 to OUT2 and output to external devices.
Output terminal
Default assignment
OUT0
OR (Total judgement)
OUT1
BUSY
OUT2
ERROR
Note
The timing for updating the OR0 to OR31 signals and the ON time after judgement processing can be changed.
Adjusting the judgement output timing: p. 42
Important
During Sensor startup, the user output assignments of OUT1 and OUT2 output terminals are not effective. The output
assignments assume the initial state and operate as follows.
• OUT1: Turns ON as a BUSY signal.
Operation When the Sensor Power Supply Is Turned ON: p.34
• OUT2: Turns ON as an ERROR signal for about 20 ms immediately after sensor startup starts.
If you want to output a READY signal during Sensor startup, assign the READY signal to OUT0.
Wiring
Example: Signals are assigned to terminals OUT0 to OUT2 as shown below.
OUT0: Item 2 judgement (OR2)
OUT1: Item 5 judgement (OR5)
OUT2: Item 14 judgement (OR14)
Color
Signal
Black
OUT0 (OR2)
Orange
OUT1 (OR5)
Light
OUT2 (OR14)
blue
As described above, if terminals OUT0 to OUT2 are all assigned to individual judgement output signals, the
BUSY signal and ERROR signal assigned as the default settings will no longer be output.
FQ2-S/CH User's Manual
for Communications Settings
• Control signals: OR, BUSY, ERROR, READY, and RUN STG (strobe trigger)
• Item judgements: OR0 (Item 0 judgement) to OR31 (Item 31 judgement)
• Expression judgements: Expression 0 judgement to expression 31 judgement
Description
Outputs the judgement for
OR2.
Outputs the judgement for
OR5.
Outputs the judgement for
OR14.
Controlling Operation and Outputting Data with the Sensor's Standard Parallel Connection
Output signals that can be assigned
The signals shown at the left are used.
Refer to the following information for signal wiring.
Section 2 Installation and Connections
in Sensor FQ2-S/CH Series
User's Manual (Cat. No. Z337)
41