Omron FQ2-S/CH Series User Manual page 272

Smart camera
Hide thumbs Also See for FQ2-S/CH Series:
Table of Contents

Advertisement

Save Image Data
Saves image data saved in the Sensor's memory by the logging function to the SD card inserted in the Touch
Finder as ifz data.
The destination for image data is the following fixed directory on the SD card.
\Sensor name\LOGIMAGE\Number*1
*1
Number is a five digit number starting from 00000. The images are saved in increments of 100 images for each number, and when there
are over 100 images, the directory with the next number is created.
The file name is not case sensitive. The file name extension can be omitted.
Command (PLC to Sensor)
First word of com-
mand area
+2
+3
+4
+5
+6
:
+37
*1
When using the EtherNet/IP or PROFINET communication protocol, the file name is automatically created as follows.
img_ScnNNN_YYYY_MM_DD-HH_mm_ss(S)_TTTT_XX.ifz
img
ScnNNN
YYYY_MM_DD
HH_mm_ss
(S)
TTTT
XX
*1
The date and time are not recorded in the image data. Therefore, this is not the date and time that the measurement was performed, this
is the date and time the image data file was saved from the Sensor to the Touch Finder SD card by this command.
For example, when performing the 10th measurement with scene 1 after the Sensor's power supply has been turned on, and the execution
time of this command is December 5, 2013, at 22:10:21
img_Scn001_2013_12_05-22_01_21(1)_10_OK.ifz
Response (Sensor to PLC)
First word of
response area
+2
+3
+4
+5
270
Command Control
Bits
12 to 15
8 to 11
4 to 7
0100
0000
0000
0000
0000
0111
0000
0000
0000
0000
0000
0000
0000
0000
0000
:
:
0000
0000
0000
Prefix string. The string can be set as desired with the following setting.
(Setup Mode or Run Mode) − [TF settings] − [File format]
Scn + measured scene number (0 to 31)
Date that the image data was saved to the Touch Finder SD card
Time that the image data was saved to the Touch Finder SD card
Image data number (0 to 19)
Number of measurements since the Sensor was started. Reset when the power supply is
turned OFF.
Total judgment (OK/NG)
Bits
12 to 15
8 to 11
4 to 7
0100
0000
0000
0000
0000
0111
0000
0000
0000
0000
0000
0000
0 to 3
0000
Command code
0000
0000
Image data No.
0000
0000
File name*1 (only when using the PLC link
communication protocol)
:
:
File name to save. 64 characters max.
The file name extension (.ifz) can be omitted.
0000
Refer to Specifying Character Strings:
p. 206
0 to 3
0000
Command code
Response target command codes
0000
0000
Response code
Command execution result
0000
0: OK, FFFFFFFF: NG
Contents
*1
*1
Contents
FQ2-S/CH User's Manual
for Communications Settings

Advertisement

Table of Contents
loading

Table of Contents