Save Scene Data
This command saves scene data to the SD card inserted in the Touch Finder as a file.
The destination for scene data is the following fixed directory on the SD card.
\Sensor name\SCN
The file name is not case sensitive. The file name extension can be omitted.
Command (PLC to Sensor)
First word of com-
mand area
12 to 15
+2
0001
+3
0000
+4
0000
+5
0000
+6
0000
+7
0000
+8
0000
:
0000
+37
0000
*1
Saved as a file named Scene_***.scn. (***: Specified file number)
Response (Sensor to PLC)
First word of
response area
12 to 15
+2
0001
+3
0000
+4
0000
+5
0000
FQ2-S/CH User's Manual
for Communications Settings
Bits
8 to 11
4 to 7
0 to 3
0000
0000
0000
0000
0111
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
Bits
8 to 11
4 to 7
0 to 3
0000
0000
0000
0000
0111
0000
0000
0000
0000
0000
0000
0000
Contents
Command code
Number of the scene to be saved.
• EtherNet/IP,
• PLC link
PROFINET
File name to save
64 characters max.
File number to load
The file name exten-
(0 to 999)*1
sion (.scn) can be
omitted.
---
Specifying Character
Strings: p. 206
Contents
Command code
Response target command codes
Response code
Command execution result
0: OK, FFFFFFFF: NG
Refer to