Fuel Cut-Off Relay - Honda INTERCEPTOR 2002 Service Manual

Table of Contents

Advertisement

FUEL SYSTEM (Programmed Fuel Injection)
FUEL FLOW INSPECTION
Remove the upper cowl (page
2-12).
Open
and support
the
fuel
ta
nk
using the
equipped
tools (page
3-5).
Disconnect the fuel cut-off relay connector.
Jump
the Brown and
Black/white wire terminals of
. - - -
--
-- - - -
-- -
-- - - - - ,
the wire
harness
side
using a jumper
wire.
FUEL
CUT-OFF
RELAY
When the fuel return hose
is
disconnected,
gaso-
line
will spill
out from
the hose. Place
a approved
gasoline container and drain the gasoline.
Wipe
off spilled
out gasoline.
Disconnect the fuel return hose at the fuel tank, plug
the fuel tank inlet joint.
Turn
the
ignition switch
ON
for 10 seconds.
Measure
the
amount
of
fuel flow.
Amount of
fu el
flow:
150 cm
3
(5.0 US
oz, 5.3 Imp
oz)
minimum
/10
seconds at 12 V
If the fuel flow is less than specified, inspect the fol-
lowing:
-
Pinched
or
clogged fuel hose and
fuel
return
hose
-
Clogged fuel filter
-
Pressure
regulator
-
Fuel pump (page 5-54)
After inspection, connect the fuel return hose.
Start
the engine
and check
for
leak.
JUMPER WIRE
CONNECTOR
FUEL RETURN
HOSE
5-53