FUEL SYSTEM
(Programmed
Fuel Injection)
5-34
Check for
loose
or
poor
contact on
the
cam pulse
r------------------~
generator 2P connector.
CAM PULSE GENERATOR 2P CONNECTOR
Connect
the
cam pulse
generator
2P
connector.
Place
the motorcycle on its
side stand.
Turn the
ignition
switch ON.
Turn the starter motor more than
10
seconds
and
t
hen
check
that
the MIL blinks.
Check that
t he
MIL blinks.
Is
the MIL blinking?
NO
- Loose or poor contact on
the
cam pulse
generator 2P connector.
YES
- GO TO STEP 2.
2. Cam Pulse Generator Short
Circuit
Inspection
Turn
the
ignition switch OFF and the engine stop
switch OFF.
Disconnect
t
he
cam pulse generator 2P connec-
tor.
CAM PULSE GENERATOR 2P CONNECTOR
~
Check the continuity
between the
cam pulse
r------------------~
generator connector terminal
and
ground.
CAM
PULSE
GENERATOR 2P CONNECTOR
Connection: White/yellow
(+)-Ground (-)
Is
there continuity?
YES
- Fau lty
cam pulse generator.
NO
- GO TO STEP 3.
3. Cam Pulse Generator Peak Voltage Inspection
Crank the engine with
the
starter
motor,
and
r------------------~
CAM
PULSE
GENERATOR
2P CONNECTOR
measure
the cam pulse generator peak voltage
at
t
he
cam pulse generator 2P connector.
Connection:
Gray(+)- White/yellow(-)
Standard:
0.7
v
minimum
(20
°C/68 °F)
Is
the
voltage
at the standard value?
No
-
Faulty
cam pulse generator.
YES
-GO TO
STEP
4.
;
c::::J