FUEL SYSTEM
(Programmed
Fuel Injection)
Inspection
Remove the bypass control solenoid valve.
Check that the air should flow
(A) to (B).
only when
the
12V
battery
is
connected to the bypass control
solenoid valve terminal.
Check the
resistance
between the terminals of the
bypass control solenoid valve.
STANDARD:
28- 32
Q
(20
°C/68
°F)
If
the resistance
is
out of specification, replace the
bypass control solenoid valve.
ONE-WAY VALVE
Removal/Installation
Remove the air cleaner housing
(page
5-60).
Disconnect the vacuum hose and the one-way
va lve.
Route the
vacuum
Installation is in
the
reve
rse
order
of
removal.
hoses
correctly
5-86
Inspection
Check the one-way valve operation as follows:
-
Air shou ld flow
(A)
to
(B)
Air should flow
(A)
to
(C)
-
Air should
not
flow
(B)
to (A)
Air should not flow
(B)
to
(C)
If the operation is
incorrect,
re
place
the one-way
valve.
(A)
BYPASS CONTROL SOLENOID VALVE
ONE-WAY VALVE

Advertisement