Honda INTERCEPTOR 2002 Service Manual page 560

Table of Contents

Advertisement

For
accurate test
Set
the temperature
switch to "HIGH
"
or
"LOW"
results,
be
sure the
depending on the
ambient
temperature.
tester's cables and
cla-nps are
m
good
conditton and that
a
secure
connec/lon
can be
made at
the
battery.
For the
f1rst check,
DO
NOT
charge the
battery before
test-
ing;
test
it tn an
·as
is'
condttlon.
Push
in the appropriate test button for 3
seconds
and
read the condition of the
battery
on the
meter.
To
avoid
damaging the
tester,
only test batteries
with an amperage
rating
of less than 30
Ah.
Tester
damage can result from overheating when:
-
The test button is pushed in for more than 3 sec-
onds.
-
The
tester is
used
w ithout
being
allowed
to
cool
for
at
least 1
minute
when testing more than one
battery.
-
More
than
10
consecutive
tests
are performed
w ithout allowing at least
a
30-minute cool-down
period
.
BATTERY
/
CHARGING
SYSTEM
u
u
HIGH
15°
C
(60°F)
or higher
LOW
15°C
(60°
F) or lowe
r
TEST
BUTTONS
The
result of
a
test
on
the
meter
sca le is
relative
to
~=================~
the amp hour
rating
of the battery. ANY
BA TIERY
READING IN THE GREEN
ZONE
IS OK.
Batteries
should
only be charged if
they
register in the YEL-
LOW or RED
zone.
BATTERY CHARGING
Remove the battery (page
17-6).
Clean the
battery terminal
s
and
posit ion the
bat-
tery as far
away from
the charger as
the
leads
w
ill
perm it.
Do
not place batteries below the charger, gases
from
the battery may corrode and damage the
charger.
Do
not
place
batteries on
top
of the charger. Be
sure the
air
vents are
not blocked.
TOOL:
Christie
battery charger
MC1012/2
(U.S.A.
only)
BLACK
GREEN
(+1
, +2, +3)
BATIERY
17-7