4.
Cam
Pulse Generator
Peak
Voltage Inspection at
ECM
Turn the ignition switch OFF.
Connect the cam pulse generator 2P connector.
Disconnect the ECM connectors.
Connect
the
test harness
to the wire harness
connectors.
Crank the
engine
with
the
starter
motor,
and
measure the cam
pulse generator peak
voltage
at the test
harness
terminals.
Connection:
A14 (+}-ground(-}
Standard:
0.7
v
minimum
(20
°C/
68
°F}
Is
the voltage standard
value?
NO
-
Open
or short
circuit
in
White/yellow
and/
or Gray wire.
YES
- Replace the ECM with a new one, and
inspect it again.
PGM-FI
MIL 19 BLINKS (IGNITION PULSE
GENERA-
TOR}
1.
Ignition Pulse Generator Connection Inspection
Turn
the ignition switch
OFF.
Disconnect
the ignition pulse
generator 2P
con-
nector.
Check for loose or poor contact on the cam pulse
generator 2P connector.
Place the motorcycle on its side stand.
Connect the cam pulse
generat
or 2P connector.
Turn
the ig nition
switch
ON.
Turn
the
starter motor
more than
10 seconds
and then check that the MIL blinks.
Check that the MIL blinks.
Is
the
MIL
blinking?
NO
- Loose or poor contact on the cam
pulse
generator 2P connector.
YES
- GO TO STEP 2.
ECM
PEAK VOLTAG
E
ADAPTOR
IGNITION PULSE GENERATOR
2P CONNECTORS
~-~
5-35