Irq_Enable_Set Register - Texas Instruments TMS320C6A816 Series Technical Reference Manual

C6-integra dsp+arm processors
Table of Contents

Advertisement

www.ti.com
Table 1-110. IRQ Enable Set Register (MAILBOX_IRQENABLE_SET_u) Field Descriptions (continued)
Bit
Field
9
NOTFULLSTATUSUUM
B4
8
NEWMSGSTATUSUUM
B4
7
NOTFULLSTATUSUUM
B3
6
NEWMSGSTATUSUUM
B3
5
NOTFULLSTATUSUUM
B2
4
NEWMSGSTATUSUUM
B2
3
NOTFULLSTATUSUUM
B1
2
NEWMSGSTATUSUUM
B1
1
NOTFULLSTATUSUUM
B0
SPRUGX9 – 15 April 2011
Submit Documentation Feedback
Preliminary
Value
Description
Not Full Status bit for User u, Mailbox 4
0
Read: No event pending (message queue full)
1
Read: Event pending (message queue not full)
0
Write: No action
1
Write: Set the event (for debug)
New Message Status bit for User u, Mailbox 4
0
Read: No event (message) pending
1
Read: Event (message) pending
0
Write: No action
1
Write: Set the event (for debug)
Not Full Status bit for User u, Mailbox 3
0
Read: No event pending (message queue full)
1
Read: Event pending (message queue not full)
0
Write: No action
1
Write: Set the event (for debug)
New Message Status bit for User u, Mailbox 3
0
Read: No event (message) pending
1
Read: Event (message) pending
0
Write: No action
1
Write: Set the event (for debug)
Not Full Status bit for User u, Mailbox 2
0
Read: No event pending (message queue full)
1
Read: Event pending (message queue not full)
0
Write: No action
1
Write: Set the event (for debug)
New Message Status bit for User u, Mailbox 2
0
Read: No event (message) pending
1
Read: Event (message) pending
0
Write: No action
1
Write: Set the event (for debug)
Not Full Status bit for User u, Mailbox 1
0
Read: No event pending (message queue full)
1
Read: Event pending (message queue not full)
0
Write: No action
1
Write: Set the event (for debug)
New Message Status bit for User u, Mailbox 1
0
Read: No event (message) pending
1
Read: Event (message) pending
0
Write: No action
1
Write: Set the event (for debug)
Not Full Status bit for User u, Mailbox 0
0
Read: No event pending (message queue full)
1
Read: Event pending (message queue not full)
0
Write: No action
1
Write: Set the event (for debug)
© 2011, Texas Instruments Incorporated
Mailbox
231
Chip Level Resources

Advertisement

Table of Contents
loading