1.14.3 Functional Description; Local Power Management Features - Texas Instruments TMS320C6A816 Series Technical Reference Manual

C6-integra dsp+arm processors
Table of Contents

Advertisement

www.ti.com

1.14.3 Functional Description

1.14.3.1 Software Reset
The Spinlock module can be reset by software through the SPINLOCK_SYSCONFIG[1] SOFTRESET bit.
Setting this bit to 1 enables an active software reset that is functionally equivalent to a hardware reset.
This bit also indicates that the software reset is complete when its value is reset to 0. The software must
ensure that the software reset completes before doing Spinlock operations.
1.14.3.2 Power Management
Table 1-114
describes power-management features available to the Spinlock module.
Feature
Clock auto gating
Slave idle modes
Clock activity
Global wake-up enable
NOTE: All the local power management features are non-configurable (that is, their respective bits
or bit fields are read-only).
The PRCM module has no hardware means of reading CLOCKACTIVITY
settings. Thus, software must ensure consistent programming between the
CLOCKACTIVITY bit and Spinlock clock PRCM control bits.
The Spinlock module is normally idle, except when processing a request from its slave interface port. The
smart-idle mode acknowledges idle requests from the PRCM only when the module is prepared to go idle.
The Spinlock module is always ready to go idle if it does not have any request that it is processing.
The Spinlock module uses retention flops to retain state including the Taken state of each lock register.
This means that the module can be placed in retention at any time when it is not processing a request and
it is known that the system will not need to access the module.
Software must ensure to only power off the Spinlock module when no locks would be lost. In general, the
steps to powering down the Spinlock module are:
Check that all masters which might use the Spinlock module are either:
– Already powered off
– Notified that Spinlock is not available and the notification is acknowledged
If desired, check that no locks are currently held in the Spinlock module. The status of each bank of 64
locks can be read from the register. If any locks are held, they are orphaned because they are not held
by any master that is still active. Alternatively, you may decide to wait a timeout period to allow any
active master to clean up its locks before powering down.
The Spinlock module can now be powered off by writing the appropriate status to the PRCM.
In the case of powering off the whole system, these steps are unnecessary.
SPRUGX9 – 15 April 2011
Submit Documentation Feedback
Preliminary
Table 1-114. Local Power Management Features
Registers
[0] AUTOGATING bit
[4:3] SIDLEMODE bit field
[8] CLOCKACTIVITY bit
[2] ENAWAKEUP bit
CAUTION
© 2011, Texas Instruments Incorporated
Description
This bit indicates that the module uses an
automatic internal interface clock gating
strategy, based on interface activity.
This bit field indicates that the module
uses smart-idle mode.
This bit indicates that the interface clock is
not required by the module during idle
mode and may be switched off.
This bit indicates that the wake-up
generation feature (at module level) is
disabled.
Chip Level Resources