18.3.1.11 BATUPD Register (Offset = 2Ch) [reset = 0h]
BATUPD is shown in
Battery Update
Indicates BAT Updates
31
30
23
22
15
14
7
6
Bit
Field
31-1
RESERVED
0
STAT
SWCU117C – February 2015 – Revised September 2015
Submit Documentation Feedback
Figure 18-11
and described in
Figure 18-11. BATUPD Register
29
28
RESERVED
21
20
RESERVED
13
12
RESERVED
5
4
RESERVED
R-0h
Table 18-12. BATUPD Register Field Descriptions
Type
Reset
R
0h
R/W1C
0h
Copyright © 2015, Texas Instruments Incorporated
Table
18-12.
27
26
R-0h
19
18
R-0h
11
10
R-0h
3
2
Description
Software must not rely on the value of a reserved. Writing any other
value than the reset value may result in undefined behavior.
0: No update since last clear
1: New battery voltage is present.
Write 1 to clear the status.
Battery Monitor and Temperature Sensor
BATMON Registers
25
24
17
16
9
8
1
0
STAT
R/W1C-0h