17.7.7.16 MCUBUSSTAT Register (Offset = 4Ch) [reset = 0h]
MCUBUSSTAT is shown in
MCU Bus Status
Indicates the connection state of the AUX domain and MCU domain buses.
Note that this register cannot be read from the MCU domain while disconnected, and is therefore only
useful for the AUX_SCE.
31
30
23
22
15
14
7
6
Bit
Field
31-2
RESERVED
1
DISCONNECTED
0
DISCONNECT_ACK
SWCU117C – February 2015 – Revised September 2015
Submit Documentation Feedback
Figure 17-77
and described in
Figure 17-77. MCUBUSSTAT Register
29
28
RESERVED
R-0h
21
20
RESERVED
R-0h
13
12
RESERVED
R-0h
5
4
RESERVED
R-0h
Table 17-102. MCUBUSSTAT Register Field Descriptions
Type
Reset
R
0h
R
0h
R
0h
Copyright © 2015, Texas Instruments Incorporated
AUX – Sensor Controller Registers
Table
17-102.
27
26
19
18
11
10
3
2
Description
Software must not rely on the value of a reserved. Writing any other
value than the reset value may result in undefined behavior.
Indicates whether the AUX domain and MCU domain buses are
currently disconnected (1) or connected (0).
Acknowledges reception of the bus disconnection request, by
matching the value of MCUBUSCTL.DISCONNECT_REQ.
Note that if AON_WUC:AUXCTL.AUX_FORCE_ON = 1 a reconnect
to the MCU domain bus will be made regardless of the state of
MCUBUSCTL.DISCONNECT_REQ
AUX – Sensor Controller with Digital and Analog Peripherals
25
24
17
16
9
8
1
0
DISCONNECT
DISCONNECT
ED
_ACK
R-0h
R-0h
1311