Download Print this page

Texas Instruments SimpleLink CC2620 Technical Reference Manual page 1546

Zigbee rf4ce wireless mcu simplelink cc13 series; simplelink cc26 series

Advertisement

Bluetooth Low Energy
Byte
Field Name
Index
0–1
commandNo
2
payloadType
3
newLen
4–7
pNewData
8–11
pParams
23.6.1.2 Parameter Structures
Byte Index Field Name
0–3
pRxQ
4–7
pTxQ
8
rxConfig
9
seqStat
10
maxNack
11
maxPkt
12–15
accessAddress
16–18
crcInit
19
timeoutTrigger
20–23
timeoutTime
24–26
27
endTrigger
28–31
endTime
Byte Index Field Name
0–3
pRxQ
4–7
pTxQ
8
rxConfig
9
seqStat
10
maxNack
11
maxPkt
12–15
accessAddress
16–18
crcInit
19
endTrigger
20–23
endTime
1546
Radio
Table 23-90. Update Advertising Payload Command
Type
W
W
W
W
W
Table 23-91. Slave Commands
Type
W
W
W
R/W
W
W
W
W
W
W
W
W
Table 23-92. Master Commands
Type
W
W
W
R/W
W
W
W
W
W
W
Copyright © 2015, Texas Instruments Incorporated
Description
The command number
0: Advertising data
1: Scan response data
Length of the new payload
Pointer to the buffer containing the new data
Pointer to the parameter structure to update
Description
Pointer to receive queue
Pointer to transmit queue
Configuration bits for the receive queue entries (see
Table 23-104
for details)
Sequence number status (see
Table 23-70
Maximum number of NACKs received before operation
ends. 0: No limit
Maximum number of packets transmitted in the operation
before it ends. 0: No limit
Access address used on the connection
CRC initialization value used on the connection
Trigger that defines timeout of the first receive operation
Time parameter for timeoutTrigger
Reserved
Trigger that causes the device to end the connection event
as soon as allowed
Time parameter for endTrigger
Description
Pointer to receive queue
Pointer to transmit queue
Configuration bits for the receive queue entries (see
Table 23-104
for details)
Sequence number status (see
Table 23-70
Maximum number of NACKs received before operation
ends. 0: No limit
Maximum number of packets transmitted in the operation
before it ends. 0: No limit
Access address used on the connection
CRC initialization value used on the connection
Trigger that causes the device to end the connection event
as soon as allowed
Time parameter for endTrigger
SWCU117C – February 2015 – Revised September 2015
Submit Documentation Feedback
www.ti.com
for details)
for details)

Hide quick links:

Advertisement

loading