Real-Time Clock Registers
14.4.1.11 CH1CAPT Register (Offset = 28h) [reset = 0h]
CH1CAPT is shown in
Channel 1 Capture Value
If CHCTL.CH1_EN = 1and CHCTL.CH1_CAPT_EN = 1, capture occurs on each rising edge of the event
selected in AON_EVENT:RTCSEL.
31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10
Bit
Field
31-16
SEC
15-0
SUBSEC
1142
Real-Time Clock
Figure 14-12
and described in
Figure 14-12. CH1CAPT Register
SEC
R-0h
Table 14-12. CH1CAPT Register Field Descriptions
Type
Reset
R
0h
R
0h
Copyright © 2015, Texas Instruments Incorporated
Table
14-12.
9
SUBSEC
Description
Value of SEC.VALUE bits 15:0 at capture time.
Value of SUBSEC.VALUE bits 31:16 at capture time.