Download Print this page

Texas Instruments SimpleLink CC2620 Technical Reference Manual page 1103

Zigbee rf4ce wireless mcu simplelink cc13 series; simplelink cc26 series

Advertisement

www.ti.com
Bit
Field
7-6
RESERVED
5
DMAARIS
4
TAMRIS
3
RTCRIS
2
CAERIS
1
CAMRIS
0
TATORIS
SWCU117C – February 2015 – Revised September 2015
Submit Documentation Feedback
Table 13-14. RIS Register Field Descriptions (continued)
Type
Reset
R
0h
R
0h
R
0h
R
0h
R
0h
R
0h
R
0h
Copyright © 2015, Texas Instruments Incorporated
Description
Software must not rely on the value of a reserved. Writing any other
value than the reset value may result in undefined behavior.
GPT Timer A DMA Done Raw Interrupt Status
0: Transfer has not completed
1: Transfer has completed
**GPT **Timer A Match Raw Interrupt
0: The match value has not been reached
1: The match value is reached.
TAMR.TAMIE is set, and the match values in TAMATCHR and
optionally TAPMR have been reached when configured in one-shot
or periodic mode.
GPT RTC Raw Interrupt
0: The RTC event has not occured
1: The RTC event has occured
GPT Timer A Capture Mode Event Raw Interrupt
0: The event has not occured.
1: The event has occured.
This interrupt asserts when the subtimer is configured in Input Edge-
Time mode
GPT Timer A Capture Mode Match Raw Interrupt
0: Match for Timer A has not occured
1: Match for Timer A has occurred
This interrupt asserts when the values in the TAR and TAPR match
values in the TAMATCHR and TAPMR, and when configured in
Input Edge-Time mode (reg-ref instead!!)
GPT Timer A Time-out Raw Interrupt
0: Timer A has not timed out
1: Timer A has timed out.
This interrupt is asserted when a one-shot or periodic mode timer
reaches its count limit. The count limit is 0 or the value loaded into
TAILR, depending on the count direction.
General-purpose Timer Registers
Timers
1103