Table 23-167. RFHWIFG Register Field Descriptions (continued)
Bit
Field
5
MDMSOFT
4
MDMOUT
3
MDMIN
2
MDMDONE
1
FSCA
0
RESERVED
SWCU117C – February 2015 – Revised September 2015
Submit Documentation Feedback
Type
Reset
Description
R/W
0h
Modem synchronization word detection interrupt flag. This interrupt
will be raised by modem when the synchronization word is received.
The CPE may decide to reject the packet based on its header
(protocol specific). Write zero to clear flag. Write to one has no
effect.
R/W
0h
Modem FIFO output interrupt flag. Write zero to clear flag. Write to
one has no effect.
R/W
0h
Modem FIFO input interrupt flag. Write zero to clear flag. Write to
one has no effect.
R/W
0h
Modem command done interrupt flag. Write zero to clear flag. Write
to one has no effect.
R/W
0h
Frequency synthesizer calibration accelerator interrupt flag. Write
zero to clear flag. Write to one has no effect.
R/W
0h
Software must not rely on the value of a reserved. Writing any other
value than the reset value may result in undefined behavior.