17.7.4.7 SMPH6 Register (Offset = 18h) [reset = 1h]
SMPH6 is shown in
Semaphore 6
31
30
23
22
15
14
7
6
Bit
Field
31-1
RESERVED
0
STAT
1268
AUX – Sensor Controller with Digital and Analog Peripherals
Figure 17-43
and described in
Figure 17-43. SMPH6 Register
29
28
RESERVED
21
20
RESERVED
13
12
RESERVED
5
4
RESERVED
R-0h
Table 17-65. SMPH6 Register Field Descriptions
Type
Reset
R
0h
R/W
1h
Copyright © 2015, Texas Instruments Incorporated
Table
17-65.
27
26
R-0h
19
18
R-0h
11
10
R-0h
3
2
Description
Software must not rely on the value of a reserved. Writing any other
value than the reset value may result in undefined behavior.
Status when reading:
0: Semaphore was already taken
1: Semaphore was available and hence taken by this read access
Reading the register causes it to change value to 0. Releasing the
semaphore is done by writing 1.