19.7.1.9 IFLS Register (Offset = 34h) [reset = 12h]
IFLS is shown in
Figure 19-12
Interrupt FIFO Level Select
31
30
29
28
15
14
13
12
Bit
Field
31-6
RESERVED
5-3
RXSEL
2-0
TXSEL
SWCU117C – February 2015 – Revised September 2015
Submit Documentation Feedback
and described in
Table
Figure 19-12. IFLS Register
27
26
25
24
RESERVED
R/W-0h
11
10
9
8
RESERVED
R/W-0h
Table 19-12. IFLS Register Field Descriptions
Type
Reset
R/W
0h
R/W
2h
R/W
2h
Copyright © 2015, Texas Instruments Incorporated
19-12.
23
22
21
20
7
6
5
4
RXSEL
R/W-2h
Description
Software must not rely on the value of a reserved. Writing any other
value than the reset value may result in undefined behavior.
Receive interrupt FIFO level select:
This field sets the trigger points for the receive interrupt. Values
0b101-0b111 are reserved.
0h = 1_8 : Receive FIFO becomes >= 1/8 full
1h = 2_8 : Receive FIFO becomes >= 1/4 full
2h = 4_8 : Receive FIFO becomes >= 1/2 full
3h = 6_8 : Receive FIFO becomes >= 3/4 full
4h = 7_8 : Receive FIFO becomes >= 7/8 full
Transmit interrupt FIFO level select:
This field sets the trigger points for the transmit interrupt. Values
0b101-0b111 are reserved.
0h = 1_8 : Transmit FIFO becomes <= 1/8 full
1h = 2_8 : Transmit FIFO becomes <= 1/4 full
2h = 4_8 : Transmit FIFO becomes <= 1/2 full
3h = 6_8 : Transmit FIFO becomes <= 3/4 full
4h = 7_8 : Transmit FIFO becomes <= 7/8 full
Universal Asynchronous Receivers and Transmitters (UARTS)
UARTS Registers
19
18
17
16
3
2
1
0
TXSEL
R/W-2h