BATMON Registers
18.3.1.2 MEASCFG Register (Offset = 4h) [reset = 0h]
MEASCFG is shown in
Internal. Only to be used through TI provided API.
31
30
29
28
15
14
13
12
Bit
Field
31-2
RESERVED
1-0
PER
1326
Battery Monitor and Temperature Sensor
Figure 18-2
and described in
Figure 18-2. MEASCFG Register
27
26
25
24
RESERVED
R-0h
11
10
9
8
RESERVED
R-0h
Table 18-3. MEASCFG Register Field Descriptions
Type
Reset
R
0h
R/W
0h
Copyright © 2015, Texas Instruments Incorporated
Table
18-3.
23
22
21
20
7
6
5
4
Description
Internal. Only to be used through TI provided API.