Texas Instruments SimpleLink CC2620 Technical Reference Manual page 1280

Zigbee rf4ce wireless mcu simplelink cc13 series; simplelink cc26 series

Advertisement

AUX – Sensor Controller Registers
17.7.5.7 TRIGCNTLOAD Register (Offset = 18h) [reset = 0h]
TRIGCNTLOAD is shown in
Trigger Counter Load
Stop counter control of TDC
31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10
RESERVED
Bit
Field
31-16
RESERVED
15-0
CNT
1280
AUX – Sensor Controller with Digital and Analog Peripherals
Figure 17-52
and described in
Figure 17-52. TRIGCNTLOAD Register
R-0h
Table 17-75. TRIGCNTLOAD Register Field Descriptions
Type
Reset
R
0h
R/W
0h
Copyright © 2015, Texas Instruments Incorporated
Table
17-75.
9
R/W-0h
Description
Software must not rely on the value of a reserved. Writing any other
value than the reset value may result in undefined behavior.
Selects the number of stop events that will be ignored by the TDC.
This can be used to measure multiple periods of a clock signal. The
value written to this field is loaded into the stop counter at the start of
each measurement.
Note! Both values 0 and 1 will make the TDC stop on the first event
after the start event
Note! Must not be changed if STAT.STATE is not IDLE
SWCU117C – February 2015 – Revised September 2015
www.ti.com
8
7
6
5
4
3
2
1
CNT
Submit Documentation Feedback
0