AUX – Sensor Controller Registers
17.7.6.5 T1TARGET Register (Offset = 10h) [reset = 0h]
T1TARGET is shown in
Timer 1 Target
Target Counter Value Timer 1
31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10
Bit
Field
31-8
RESERVED
7-0
VALUE
1292
AUX – Sensor Controller with Digital and Analog Peripherals
Figure 17-60
and described in
Figure 17-60. T1TARGET Register
RESERVED
R-0h
Table 17-84. T1TARGET Register Field Descriptions
Type
Reset
R
0h
R/W
0h
Copyright © 2015, Texas Instruments Incorporated
Table
17-84.
9
Description
Software must not rely on the value of a reserved. Writing any other
value than the reset value may result in undefined behavior.
Timer 1 counts from 0 to VALUE. Then gives an event and restarts if
configured to do to so in the T1CFG.RELOAD setting. If VALUE is
changed while timer 1 is running so that the count becomes higher
than VALUE timer 1 will also restart if configured to do so.
If T1CFG.MODE=0,no prescaler is used, and VALUE equals 1, the
TIMER1_EV event line will be always set