13.5.1.5 SYNC Register (Offset = 10h) [reset = 0h]
SYNC is shown in
Synch Register
31
30
29
28
15
14
13
12
RESERVED
Bit
Field
31-8
RESERVED
7-6
SYNC3
5-4
SYNC2
3-2
SYNC1
1-0
SYNC0
SWCU117C – February 2015 – Revised September 2015
Submit Documentation Feedback
Figure 13-13
and described in
Figure 13-13. SYNC Register
27
26
25
11
10
9
R-0h
Table 13-12. SYNC Register Field Descriptions
Type
Reset
R
0h
W
0h
W
0h
W
0h
W
0h
Copyright © 2015, Texas Instruments Incorporated
Table
13-12.
24
23
22
21
RESERVED
R-0h
8
7
6
5
SYNC3
SYNC2
W-0h
W-0h
Description
Software must not rely on the value of a reserved. Writing any other
value than the reset value may result in undefined behavior.
Synchronize GPT Timer 3.
0h = No Sync. GPT3 is not affected.
1h = A timeout event for Timer A of GPT3 is triggered
2h = A timeout event for Timer B of GPT3 is triggered
3h = A timeout event for both Timer A and Timer B of GPT3 is
triggered
Synchronize GPT Timer 2.
0h = No Sync. GPT2 is not affected.
1h = A timeout event for Timer A of GPT2 is triggered
2h = A timeout event for Timer B of GPT2 is triggered
3h = A timeout event for both Timer A and Timer B of GPT2 is
triggered
Synchronize GPT Timer 1
0h = No Sync. GPT1 is not affected.
1h = A timeout event for Timer A of GPT1 is triggered
2h = A timeout event for Timer B of GPT1 is triggered
3h = A timeout event for both Timer A and Timer B of GPT1 is
triggered
Synchronize GPT Timer 0
0h = No Sync. GPT0 is not affected.
1h = A timeout event for Timer A of GPT0 is triggered
2h = A timeout event for Timer B of GPT0 is triggered
3h = A timeout event for both Timer A and Timer B of GPT0 is
triggered
General-purpose Timer Registers
20
19
18
17
4
3
2
1
SYNC1
SYNC0
W-0h
W-0h
Timers
16
0
1099

Hide quick links:

Advertisement