Download Print this page

Texas Instruments SimpleLink CC2620 Technical Reference Manual page 1624

Zigbee rf4ce wireless mcu simplelink cc13 series; simplelink cc26 series

Advertisement

Radio Registers
Table 23-173. SYSGPOCTL Register Field Descriptions (continued)
Bit
Field
7-4
GPOCTL1
3-0
GPOCTL0
1624
Radio
Type
Reset
Description
R/W
0h
RF Core GPO control bit 1. Selects which signal to output on the RF
Core GPO line 1.
0h = CPE GPO line 0
1h = CPE GPO line 1
2h = CPE GPO line 2
3h = CPE GPO line 3
4h = MCE GPO line 0
5h = MCE GPO line 1
6h = MCE GPO line 2
7h = MCE GPO line 3
8h = RFE GPO line 0
9h = RFE GPO line 1
Ah = RFE GPO line 2
Bh = RFE GPO line 3
Ch = RAT GPO line 0
Dh = RAT GPO line 1
Eh = RAT GPO line 2
Fh = RAT GPO line 3
R/W
0h
RF Core GPO control bit 0. Selects which signal to output on the RF
Core GPO line 0.
0h = CPE GPO line 0
1h = CPE GPO line 1
2h = CPE GPO line 2
3h = CPE GPO line 3
4h = MCE GPO line 0
5h = MCE GPO line 1
6h = MCE GPO line 2
7h = MCE GPO line 3
8h = RFE GPO line 0
9h = RFE GPO line 1
Ah = RFE GPO line 2
Bh = RFE GPO line 3
Ch = RAT GPO line 0
Dh = RAT GPO line 1
Eh = RAT GPO line 2
Fh = RAT GPO line 3
Copyright © 2015, Texas Instruments Incorporated
SWCU117C – February 2015 – Revised September 2015
Submit Documentation Feedback
www.ti.com

Hide quick links:

Advertisement

loading