AUX – Sensor Controller Registers
17.7.7.13 RTCSUBSECINC1 Register (Offset = 40h) [reset = 0h]
RTCSUBSECINC1 is shown in
Real Time Counter Sub Second Increment 1
New value for the real-time counter (AON_RTC) sub-second increment value, part corresponding to
AON_RTC:SUBSECINC bits 23:16.
After setting RTCSUBSECINC0.INC15_0 and INC23_16, the value is loaded into
AON_RTC:SUBSECINC.VALUEINC by setting RTCSUBSECINCCTL.UPD_REQ.
31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10
Bit
Field
31-8
RESERVED
7-0
INC23_16
1308
AUX – Sensor Controller with Digital and Analog Peripherals
Figure 17-74
and described in
Figure 17-74. RTCSUBSECINC1 Register
RESERVED
R-0h
Table 17-99. RTCSUBSECINC1 Register Field Descriptions
Type
Reset
R
0h
R/W
0h
Copyright © 2015, Texas Instruments Incorporated
Table
17-99.
9
Description
Software must not rely on the value of a reserved. Writing any other
value than the reset value may result in undefined behavior.
Bits 23:16 of the RTC sub-second increment value.