AUX – Sensor Controller Registers
17.7.7.11 REFCLKCTL Register (Offset = 38h) [reset = 0h]
REFCLKCTL is shown in
Reference Clock Control
Controls the TDC reference clock source, which is to be compared against the TDC counter clock.
The source of this clock is controlled by OSC_DIG:CTL0.ACLK_REF_SRC_SEL.
31
30
29
28
15
14
13
12
Bit
Field
31-2
RESERVED
1
ACK
0
REQ
1306
AUX – Sensor Controller with Digital and Analog Peripherals
Figure 17-72
and described in
Figure 17-72. REFCLKCTL Register
27
26
25
24
RESERVED
R-0h
11
10
9
8
RESERVED
R-0h
Table 17-97. REFCLKCTL Register Field Descriptions
Type
Reset
R
0h
R
0h
R/W
0h
Copyright © 2015, Texas Instruments Incorporated
Table
17-97.
23
22
21
20
7
6
5
4
Description
Software must not rely on the value of a reserved. Writing any other
value than the reset value may result in undefined behavior.
Acknowledges the last value written to REQ.
Enables (1) or disables (0) the TDC reference clock source.