Byte Index
Field Name
0–3
pRxQ
4
rxConfig
5
bRepeat
6–7
8–11
accessAddress
12–14
crcInit
15
endTrigger
16–19
endTime
Byte Index
Field Name
0–1
numPackets
2
payloadLength
3
packetType
4–7
period
8
config
9
byteVal
10
11
endTrigger
12–15
endTime
SWCU117C – February 2015 – Revised September 2015
Submit Documentation Feedback
Table 23-96. Generic RX Command
Type
W
W
W
W
W
W
W
Table 23-97. TX Test Command
Bits
Bit Field Name
0
bOverride
1
bUsePrbs9
2
bUsePrbs15
Copyright © 2015, Texas Instruments Incorporated
Bluetooth Low Energy
Description
Pointer to receive queue. May be NULL; if so,
received packets are not stored
Configuration bits for the receive queue entries (see
Table 23-104
for details)
0: End operation after receiving a packet.
1: Restart receiver after receiving a packet.
Reserved
Access address used on the connection
CRC initialization value used on the connection
Trigger that causes the device to end the RX
operation
Time parameter for endTrigger
Type
Description
Number of packets to transmit
W
0: Transmit unlimited number of
packets
The number of payload bytes in each
W
packet.
W
The packet type to be used
Number of radio timer cycles between
W
the start of each packet
0: Use default packet encoding
W
1: Override packet contents
If bOverride is 1:
W
1: Use PRBS9 encoding of packet
If bOverride is 1:
W
1: Use PRBS15 encoding of packet
If config.bOverride is 1, value of each
W
byte to be sent
Reserved
Trigger that causes the device to end
W
the Test TX operation
W
Time parameter for endTrigger