23.7.2.3 Other Structures and Bit Fields
Table 23-143. Carrier Sense Fields for CMD_PROP_CS (Only Applicable for CC13xx)
Byte
Field Name
Index
0
csConf
1
rssiThr
2
numRssiIdle
3
numRssiBusy
4–5
corrPeriod
6
corrConfig
7
csEndTrigger
8–11
csEndTime
1584 Radio
Bits
Bit Field Name
0
bEnaRssi
1
bEnaCorr
2
operation
3
busyOp
4
idleOp
5
timeoutRes
0–3
numCorrInv
4–7
numCorrBusy
Copyright © 2015, Texas Instruments Incorporated
Type
Description
W
If 1, enable RSSI as a criterion
W
If 1, enable correlation as a criterion
0: Busy if either RSSI or correlation indicates
Busy
W
1: Busy if both RSSI and correlation indicates
Busy
0: Continue carrier sense on channel Busy
1: End carrier sense on channel Busy
W
For an RX command, the receiver continues
when carrier sense ends, then it does not end
if the channel goes Idle
0: Continue on channel Idle
W
1: End on channel Idle
0: Timeout with channel state Invalid treated as
Busy
W
1: Timeout with channel state Invalid treated as
Idle
W
RSSI threshold
Number of consecutive RSSI measurements
W
below the threshold needed before the channel
is declared Idle
Number of consecutive RSSI measurements
W
above the threshold needed before the channel
is declared Busy
Number of RAT ticks for a correlation
W
observation periods
Number of subsequent correlation tops with
W
maximum corrPeriod RAT ticks between them
needed to go from Idle to Invalid
Number of subsequent correlation tops with
W
maximum corrPeriod RAT ticks between them
needed to go from Invalid to Busy
W
Trigger classifier for ending the carrier sense
W
Time to end carrier sense
SWCU117C – February 2015 – Revised September 2015