Download Print this page

Texas Instruments SimpleLink CC2620 Technical Reference Manual page 1235

Zigbee rf4ce wireless mcu simplelink cc13 series; simplelink cc26 series

Advertisement

www.ti.com
17.7.2.4 GPIODOUTSET Register (Offset = Ch) [reset = 0h]
GPIODOUTSET is shown in
General Purpose Input Output Data Out Set
Strobes for setting output data register bits
31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10
Bit
Field
31-8
RESERVED
7-0
IO7_0
SWCU117C – February 2015 – Revised September 2015
Submit Documentation Feedback
Figure 17-17
and described in
Figure 17-17. GPIODOUTSET Register
RESERVED
R-0h
Table 17-37. GPIODOUTSET Register Field Descriptions
Type
Reset
R
0h
R/W
0h
Copyright © 2015, Texas Instruments Incorporated
AUX – Sensor Controller Registers
Table
17-37.
9
Description
Software must not rely on the value of a reserved. Writing any other
value than the reset value may result in undefined behavior.
Writing 1 to one or more bit positions sets the corresponding bit or
bits in GPIODOUT.
Read value is 0x00.
AUX – Sensor Controller with Digital and Analog Peripherals
8
7
6
5
4
3
2
1
IO7_0
R/W-0h
0
1235

Hide quick links:

Advertisement

loading