Download Print this page

Texas Instruments SimpleLink CC2620 Technical Reference Manual page 1411

Zigbee rf4ce wireless mcu simplelink cc13 series; simplelink cc26 series

Advertisement

www.ti.com
21.5.1.3 SCTL Register (Offset = 4h) [reset = 0h]
SCTL is shown in
Slave Control
Note: This register shares address with SSTAT, meaning that this register functions as a control register
when written, and a status register when read.
31
30
29
28
15
14
13
12
Bit
Field
31-1
RESERVED
0
DA
SWCU117C – February 2015 – Revised September 2015
Submit Documentation Feedback
Figure 21-16
and described in
Figure 21-16. SCTL Register
27
26
25
11
10
9
RESERVED
Table 21-5. SCTL Register Field Descriptions
Type
Reset
W
0h
W
0h
Copyright © 2015, Texas Instruments Incorporated
Table
21-5.
24
23
22
21
RESERVED
W-0h
8
7
6
5
W-0h
Description
Software must not rely on the value of a reserved field. Writing any
other value may result in undefined behavior.
Device active
0: Disables the I2C slave operation
1: Enables the I2C slave operation
I
20
19
18
17
4
3
2
2
Inter-Integrated Circuit (I
C) Interface
2
C Registers
16
1
0
DA
W-0h
1411

Hide quick links:

Advertisement