Download Print this page

Texas Instruments SimpleLink CC2620 Technical Reference Manual page 1231

Zigbee rf4ce wireless mcu simplelink cc13 series; simplelink cc26 series

Advertisement

www.ti.com
17.7.2.1 GPIODOUT Register (Offset = 0h) [reset = 0h]
GPIODOUT is shown in
General Purpose Input/Output Data Out
This register is used to set data on the pads assigned to AUX
31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10
Bit
Field
31-8
RESERVED
7-0
IO7_0
SWCU117C – February 2015 – Revised September 2015
Submit Documentation Feedback
Figure 17-14
and described in
Figure 17-14. GPIODOUT Register
RESERVED
R-0h
Table 17-34. GPIODOUT Register Field Descriptions
Type
Reset
R
0h
R/W
0h
Copyright © 2015, Texas Instruments Incorporated
AUX – Sensor Controller Registers
Table
17-34.
9
Description
Software must not rely on the value of a reserved. Writing any other
value than the reset value may result in undefined behavior.
Output values for AUXIO0 through AUXIO7 (for AIODIO0) or
AUXIO8 through AUXIO15 (for AIODIO1).
AUX – Sensor Controller with Digital and Analog Peripherals
8
7
6
5
4
3
2
1
IO7_0
R/W-0h
0
1231

Hide quick links:

Advertisement

loading