AUX – Sensor Controller Registers
17.7.8.2 ADCFIFOSTAT Register (Offset = 14h) [reset = 1h]
ADCFIFOSTAT is shown in
ADC FIFO Status
FIFO can hold up to four ADC samples
31
30
23
22
15
14
7
6
RESERVED
R-0h
Bit
Field
31-5
RESERVED
4
OVERFLOW
3
UNDERFLOW
2
FULL
1
ALMOST_FULL
0
EMPTY
1318
AUX – Sensor Controller with Digital and Analog Peripherals
Figure 17-82
and described in
Figure 17-82. ADCFIFOSTAT Register
29
28
RESERVED
R-0h
21
20
RESERVED
R-0h
13
12
RESERVED
R-0h
5
4
OVERFLOW
R-0h
Table 17-108. ADCFIFOSTAT Register Field Descriptions
Type
Reset
R
0h
R
0h
R
0h
R
0h
R
0h
R
1h
Copyright © 2015, Texas Instruments Incorporated
Table
17-108.
27
26
19
18
11
10
3
2
UNDERFLOW
FULL
R-0h
R-0h
Description
Software should not rely on the value of a reserved. Writing any
other value than the reset value may result in undefined behavior.
FIFO overflow flag.
0: FIFO has not overflowed.
1: FIFO has overflowed, this flag is sticky until FIFO is flushed.
FIFO underflow flag.
0: FIFO has not underflowed
1: FIFO has underflowed, this flag is sticky until the FIFO is flushed
FIFO full flag.
0: FIFO is not full, i.e. there is less than 4 samples in the FIFO.
1: FIFO is full, i.e. there are 4 samples in the FIFO
FIFO almost full flag.
0: There is less than 3 samples in the FIFO, or the FIFO is full in
which case the FULL flag is asserted
1: There are 3 samples in the FIFO, i.e. there is room for one more
sample
FIFO empty flag.
0: FIFO contains one or more samples
1: FIFO is empty
SWCU117C – February 2015 – Revised September 2015
www.ti.com
25
24
17
16
9
8
1
0
ALMOST_FULL
EMPTY
R-0h
R-1h