AUX – Sensor Controller Registers
17.7.5.5 TRIGSRC Register (Offset = 10h) [reset = 0h]
TRIGSRC is shown in
Trigger Source
TDC start/stop trigger source selection
31
30
23
22
15
14
RESERVED
R-0h
7
6
RESERVED
R-0h
Bit
Field
31-14
RESERVED
13
STOP_POL
1276
AUX – Sensor Controller with Digital and Analog Peripherals
Figure 17-50
and described in
Figure 17-50. TRIGSRC Register
29
28
RESERVED
21
20
RESERVED
13
12
STOP_POL
R/W-0h
5
4
START_POL
R/W-0h
Table 17-73. TRIGSRC Register Field Descriptions
Type
Reset
R
0h
R/W
0h
Copyright © 2015, Texas Instruments Incorporated
Table
17-73.
27
26
R-0h
19
18
R-0h
11
10
STOP_SRC
R/W-0h
3
2
START_SRC
R/W-0h
Description
Software must not rely on the value of a reserved. Writing any other
value than the reset value may result in undefined behavior.
Polarity of stop signal. Note! Must not be changed if STAT.STATE is
not IDLE
0h = TDC stops when high level is detected
1h = TDC stops when low level is detected
SWCU117C – February 2015 – Revised September 2015
www.ti.com
25
24
17
16
9
8
1
0
Submit Documentation Feedback