20.7.1.4 SR Register (Offset = Ch) [reset = 3h]
SR is shown in
Figure 20-16
Status
31
30
29
28
15
14
13
12
Bit
Field
31-5
RESERVED
4
BSY
3
RFF
2
RNE
1
TNF
0
TFE
SWCU117C – February 2015 – Revised September 2015
Submit Documentation Feedback
and described in
Table
Figure 20-16. SR Register
27
26
25
24
RESERVED
R-0h
11
10
9
8
RESERVED
R-0h
Table 20-6. SR Register Field Descriptions
Type
Reset
R
0h
R
0h
R
0h
R
0h
R
1h
R
1h
Copyright © 2015, Texas Instruments Incorporated
20-6.
23
22
21
20
7
6
5
4
BSY
R-0h
Description
Software must not rely on the value of a reserved. Writing any other
value than the reset value may result in undefined behavior.
Serial interface busy:
0: SSI is idle.
1: SSI is currently transmitting and/or receiving a frame or the
transmit FIFO is not empty.
Receive FIFO full:
0: Receive FIFO is not full.
1: Receive FIFO is full.
Receive FIFO not empty
0: Receive FIFO is empty.
1: Receive FIFO is not empty.
Transmit FIFO not full:
0: Transmit FIFO is full.
1: Transmit FIFO is not full.
Transmit FIFO empty:
0: Transmit FIFO is not empty.
1: Transmit FIFO is empty.
Synchronous Serial Interface (SSI)
SSI Registers
19
18
17
16
3
2
1
0
RFF
RNE
TNF
TFE
R-0h
R-0h
R-1h
R-1h
1387