Show System - Enterasys 1G58x-09 Configuration Manual

Enterasys network device configuration guide
Table of Contents

Advertisement

General Configuration Command Set
Setting Basic Device Properties
3.2.2.2

show system

Use this command to display powers supply status, baud rate, timeout and other system information.
show system
Syntax Description
None.
Command Defaults
None.
Command Type
Switch command.
Command Mode
Read-Only.
Example
This example shows how to display system information:
Matrix>show system
Power Supply Status
------------------------
PS1 - Non-Operational
PS2 - Operational
System Baud : 9600
System Lockout Time : 15 minutes.
System Uptime : 0 days, 1 hours, 15 minutes, 35 seconds
System Name
------------------------ ------------------------ ------------------------
sysName
Boot Configuration: Boot from Flash
3-32
Matrix E1 Series (1G58x-09 and 1H582-xx) Configuration Guide
System Timeout : 60 minutes.
System Location
sysLocation
System Contact
sysContact