Show Spantree Portcost; Set Spantree Portcost - Enterasys 1G58x-09 Configuration Manual

Enterasys network device configuration guide
Table of Contents

Advertisement

6.2.2.8

show spantree portcost

Use this command to display cost values assigned to one or more Spanning Tree ports.
show spantree portcost port-string [sid]
Syntax Description
port-string
sid
Command Defaults
If sid is not specified, path cost information for SID 0 will be displayed.
Command Type
Switch command.
Command Mode
Read-Only.
Example
This example shows how to display the port cost for Fast Ethernet front panel port 3:
Matrix>show spantree portcost fe.0.3
Port cost = 64 for port fe.0.3.
6.2.2.9

set spantree portcost

Use this command to assign a cost value to a Spanning Tree or port. This parameter is used to
determine the best path between Spanning Tree devices. Therefore, lower values should be assigned
to ports attached to faster media, and higher values assigned to ports with slower media.
set spantree portcost port-string cost [sid]
NOTE: Port cost takes precedence over port priority (set spantree portpri). The cost
to the root is updated by each bridge at the root port.
Reviewing and Setting Spanning Tree Port Parameters
Specifies the port(s) for which to display cost values. For a
detailed description of possible port-string values, refer to
Section 4.1.2
.
(Optional) Displays cost values for a specific SID.
Matrix E1 Series (1G58x-09 and 1H582-xx) Configuration Guide
Spanning Tree Configuration Command Set
6-43

Advertisement

Table of Contents
loading

Table of Contents