Command Type
Switch command.
Command Mode
Read-Only.
Example
This example shows how to display the transmit hold count setting:
Matrix>show spantree txholdcount
Tx hold count = 3.

6.2.1.37 set spantree txholdcount

Use this command to set the maximum BPDU transmission rate. This is the number of BPDUs
which will be transmitted before transmissions are subject to a one-second timer.
set spantree txholdcount txholdcount
Syntax Description
txholdcount
Command Defaults
None.
Command Type
Switch command.
Command Mode
Read-Write.
Example
This example shows how to set the transmit hold count to 5:
Matrix>set spantree txholdcount 5
Reviewing and Setting Spanning Tree Bridge Parameters
Specifies the maximum number of BPDUs to be
transmitted before transmissions are subject to a
one-second timer. Valid values are 1 to 10. Default
value is 3.
Matrix E1 Series (1G58x-09 and 1H582-xx) Configuration Guide
Spanning Tree Configuration Command Set