Clear Spantree Maxage - Enterasys 1G58x-09 Configuration Manual

Enterasys network device configuration guide
Table of Contents

Advertisement

Syntax Description
agingtime
Command Defaults
None.
Command Type
Switch command.
Command Mode
Read-Write.
Example
This example shows how to set the maximum aging time to 25 seconds:
Matrix>set spantree maxage 25

6.2.1.24 clear spantree maxage

Use this command to reset the bridge maximum aging time to the default value of 20 seconds.
clear spantree maxage
Syntax Description
None.
Command Defaults
None.
Command Type
Switch command.
Command Mode
Read-Write.
Reviewing and Setting Spanning Tree Bridge Parameters
Specifies the maximum number of seconds that the system
retains the information received from other bridges through
STP. Valid values are 6 - 40.
Matrix E1 Series (1G58x-09 and 1H582-xx) Configuration Guide
Spanning Tree Configuration Command Set
6-25