ATTENDANT HOLD CIRCUITS
Page 36
Description
The Attendant may put an extension or trunk on hold at any one of
four HOLD positions. The system may be programmed for a call hold
recall of a variable time (see Variable Timers).
Conditions
None
Programming
For a Call Hold Recall of 20 seconds, select System Option 128
l
(Attendant-Timed Recall - Hold - 20 seconds).
For a Call Hold Recall of 40 seconds, select System Option 129
l
(Attendant-Timed Recall - Hold - 40 seconds).
neither Option 128 nor 129 is selected, the default time is 30
If
l
seconds.
Operation
To put a Call on Hold at the console:
Press the ANSWER button when call rings console.
l
Press any HOLD button (l-4); call is put on hold.
l
To Retrieve a Call on Hold at the console:
the call has been recalled by a call hold time-out, the HOLD
If
button LED will flash. Push the button (flashing) to speak with the
call "on hold".
If the call is to be recalled before a time-out, the Attendant may
press the HOLD button where the call is being held. By pressing
the HOLD button, the call will be transferred to the SOURCE or
the DESTINATION if there is a SOURCE already.
A loop start trunk may not be taken off a hold and released to
another loop start trunk
A handsfree station may not be taken off a hold and released to
another handsfree station.